Description
Description
You need accuracy for compliance, product yields, energy savings, and consistent results. The 1524 uses current reversal, a technique used in high-end instruments that eliminates thermal EMFs, for precision temperature measurements. Specifications are guaranteed from -10 °C to 60 °C ambient. Special precision resistors and a highly stable reference voltage source keep 1524 accuracy virtually insensitive to environmental temperature.
Like all Fluke handheld tools, the 1524 Reference Thermometers endure rigorous testing in temperature extremes and under harsh conditions of vibration, so you can take them anywhere you need to go.
An optional magnetic hanger allows you to hang the thermometer for easy viewing while freeing your hands to focus on the job.
Key Benefits
- Measure, graph, and record PRTs, thermocouples, and thermistors, supporting a wide range of temperature sensors.
- Accuracy up to ±0.002 °C.
- Quick sample readings in as little as 0.3 seconds.
- 1524 has two channels for simultaneous measurements, doubling productivity.
Technical Info
Specifications | |
Input channels | 2 |
Logging | 15,000 time and date stamped; 25 readings with statistics |
Sample interval (normal) |
1 second |
Sample interval (fast mode) | 0.3 seconds (see technical manual for details) |
Sensor types | PRTs, RTDs, thermistors, and thermocouples |
Thermocouple types | C, E, J, K, L, M, N, T, U, B, R, S |
Operating temperature | -10°C to 60°C (Best accuracy 13°C to 33°C) |
Power requirements | 3 AA alkaline batteries |
Size | 96 x 200 x 47 mm (3.75 x 7.9 x 1.86 in) |
Weight | 0.65 kg (1.4 lb) |
Environmental conditions for best accuracy | 13°C to 33°C |
Millivolt range and accuracy | –10 mV to 75 mV ±(0.005% + 5 μV) |
Resistance range and accuracy | 0 Ω to 400 Ω ±(0.004% + 0.002 Ω) 200 Ω to 50 kΩ ±(0.01% + 0.5 Ω) 50 kΩ to 500 kΩ ± (0.03%) |
Temperature coefficient, voltage (–10°C to 13°C, +33°C to 60°C) | ±(0.001%/°C + 1 μV/°C) |
Temperature coefficient, resistance (–10°C to 13°C, +33°C to 60°C) | 0.0008%/°C + 0.0004 Ω (0 Ω to 400 Ω) 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ) 0.06%/°C + 0.1 Ω (50 kΩ to 500 kΩ) |
Excitation current, resistance | 1 mA (0 Ω to 400 Ω) 10 μA (0 Ω to 50 kΩ) 2 µA (50 kΩ to 500 kΩ) |
Thermocouple Equivalent Temperature Accuracies (Readout Only) | |
Type B | ±0.85°C from 600°C to 800°C ±0.68°C from 800°C to 1000°C ±0.57°C from 1000°C to 1800°C |
Type C | ±0.32°C from 100ºC to 550°C ±0.71°C from 550°C to 2300°C |
Type E | ±0.52°C from -200°C to 0°C ±0.22°C from 0°C to 950°C |
Type J | ±0.52°C from -200°C to 0°C ±0.23°C from 0°C to 1200°C |
Type K | ±0.61°C from -200°C to 0°C ±0.24°C from 0°C to 1370°C |
Type L | ±0.36°C from -200°C to 0°C ±0.23°C from 0°C to 1370°C |
Type M | ±0.26°C from -20°C to 0°C ±0.25°C from 0°C to 400°C ±0.22°C from 400°C to 1400°C |
Type N | ±0.72°C from -200°C to 0°C ±0.28°C from 0°C to 1300°C |
Type R | ±1.09°C from -20°C to 0°C ±0.97°C from 0°C to 500°C ±0.49°C from 500°C to 1750°C |
Type S | ±1.05°C from -20°C to 0°C ±0.95°C from 0°C to 500°C ±0.56°C from 500°C to 1750°C |
Type T | ±0.60°C from -200°C to 0°C ±0.25°C from 0°C to 400°C |
Type U | ±0.54°C from -200°C to 0°C ±0.24°C from 0°C to 400°C |
Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction. | |
1524 Accuracies with Selected Probes (±°C) | |
-200°C | 5616-12: 0.014 5615-6: 0.025 5627A-12: 0.027 5610-9: n/a |
0°C | 5616-12: 0.021 5615-6: 0.021 5627A-12: 0.049 5610-9: 0.009 |
100°C | 5616-12: 0.027 5615-6: 0.028 5627A-12: 0.065 5610-9: 0.009 |
300°C | 5616-12: 0.040 5615-6: 0.043 5627A-12: 0.103 5610-9: n/a |
420°C | 5616-12: 0.050 5615-6: n/a 5627A-12: 0.130 5610-9: n/a |
Includes readout accuracy, probe calibration, and probe drift | |
PRT Equivalent Temperature Accuracy (Readout only) | |
–100°C | ±0.011 |
0°C | ±0.015 |
100°C | ±0.019 |
200°C | ±0.023 |
400°C | ±0.031 |
600°C | ±0.039 |
Thermistor Equivalent Temperature Accuracy (Readout Only) | |
0°C | ±0.002 |
25°C | ±0.003 |
50°C | ±0.006 |
75°C | ±0.014 |
100°C | ±0.030 |